CYNDAR Sensor Manufacturer
Offering retail and bulk orders, reliable quality, and superior service
Products Description
| safety light curtain | safety light curtain | |||
| Mode | CAT 14-30-390 2BC | |||
| Features | Number of Optical Axes | Beam Spacing | Protective Height | Scan range |
| Illustration |
|
|
|
|
| Features | 14 beams | 30mm | 390mm | 10m |
| Secure Outputs (OSSD) | 2 PNP NC | |||
| Interface Plug | M12 Connector | |||
| Package | 1 receiver and 1 transmitter, screw bracket accessories, 3-meter cable | |||
| synchronous | Line synchronization | |||
For more specifications, please refer to the user manual and contact customer service.
The 390 mm protective height of CAT 14-30-390 comes from 14 beams at 30 mm intervals, over a 466 mm total length. Through an automatic gate in material handling, the pair can stand 6 to 9 m apart and still hold 38 mm detection. Synchronisation runs on the line itself, which removes the extra pair of wires older pairs needed. Another common question concerns cable length, and the answer is that any run above 3 m is quoted with the order. Orders normally leave the works within the quoted lead time, and stock items ship the same week. Where one pair has to bridge the opening, we recommend CYNDAR light curtains.
More product descriptions
|
Product Name |
Safety Light Curtain |
|||||||
|
Relevant parameters |
||||||||
|
Light curtain type |
Transmitter and receiver through-beam |
|||||||
|
Optical axis spacing |
10mm |
14mm |
20mm |
25mm |
30mm |
40mm |
80mm |
200mm |
|
Detection accuracy |
18mm |
22mm |
28mm |
33mm |
38mm |
48mm |
88mm |
208mm |
|
Number of light beams |
6,8...32 |
6,8...32 |
4,6...32 |
6,8...32 |
4,6...32 |
4,6...32 |
4,6...20 |
4,6...12 |
|
Protection height |
Optical axis spacing × (Number of beams - 1) |
|||||||
|
Detection distance |
0.3~3m(A);0.3~6m(B);0.3~10m(C);0.3~15m(D);0.3~20m(E);0.3~25m(F);0.3~30m(G);0.3~40m(H) |
|||||||
|
Electrical data |
||||||||
|
Power supply voltage |
DC12/24V |
|||||||
|
Consumption current |
≤200mA |
|||||||
|
Response time |
≤15ms |
|||||||
|
Output |
NPN/PNP type, sink current 500mA, voltage drop below 1.5V, with polarity, short circuit, and overload protection. |
|||||||
|
Switching elements |
PNP transistor or NPN transistor |
|||||||
|
Controller
|
Light curtain controller (AC110-220V relay output) | |||||||
|
Safety relay (DC24V relay output, dual channel, manual/automatic reset selectable) |
||||||||
|
Output state |
When all optical axes are illuminated, the receiver is ON (green light indicates this). |
|||||||
|
Indicator light |
Transmitter: Power indicator (red); Receiver: Output indicator light - On (green) - Off (red) |
|||||||
|
Mechanical data |
||||||||
|
wavelength |
940nm |
|||||||
|
Light source |
Modulated Infrared LED |
|||||||
|
Cross-sectional dimensions |
51mmx35mm |
|||||||
|
Shell material |
Aluminum alloy, end caps: ABS reinforced nylon |
|||||||
|
Electrical Interfaces |
||||||||
|
Number of Interfaces |
2 (Transmitter and Receiver) |
|||||||
|
Interface Types |
7-pin M12 connector |
|||||||
|
Connection method |
Circular aviation socket, with dedicated connecting cable |
|||||||
|
Environmental Data |
||||||||
|
Protection grade |
IP65 |
|||||||
|
Resistance to light interference |
10000lux(Incident angle ≥ 5°) |
|||||||
|
Resistance to ambient light |
Incandescent light: Light intensity on the receiving surface is 3000 lux; sunlight: Light intensity on the receiving surface is 10000 lux. |
|||||||
|
Ambient temperature |
Workshop temperature: -10 to 40℃ (but not freezing); Storage temperature: -25 to 55℃ |
|||||||
|
Ambient humidity |
Workshop RH: 35~85%; Storage RH: 35~95% |
|||||||
|
Packaging |
Standard packaging (foam and cardboard box) |
|||||||
|
Allowable cable length |
100m |
|||||||
Model Description
|
Example Model: CAT 08-40-280 2AA-5m Universal Long-Distance Safety Light Curtain CAT: 8 beams, 40mm optical axis spacing, 280mm detection height, two sets of normally closed NPN outputs, 3m through-beam, 5m cable. |
|||||||
|
CAT |
08- |
40- |
280 |
2 |
A |
A |
-5m |
|
|
|
|
|
|
|
|
|
|
Product Series |
Number of beams |
Optical axis spacing |
Protection height |
Output quantity |
Output method |
Sensing distance |
Data cable length |
|
CAT |
04 06 08 ... 32 |
10:10mm 14:14mm 20:20mm 30:30mm 40:40mm 80:80mm 200:200mm |
Effective product height :Height = (Number of beams - 1) * Spacing |
2: Two sets of outputs |
A: NPN NC B: PNP NC C: NPN NO D: PNP NO |
A: 0.3-3M B: 0.3-6M C: 0.3-10M D: 0.3-15M E: 0.3-20M F: 0.3-25M G: 0.3-30M H: 0.3-40M |
Standard configuration: 3 meters (not specified) 4m: 4 meters 5m: 5 meters ... 30m: 30 meters |
|
For models with a distance greater than 10 meters and a spacing of less than 40 mm, sales confirmation is required. Note① D/E/F/G/H: Only 40 & 80mm spacing, consult tech for details |
|||||||
Factory configuration

Controller optional
|
Model |
Name |
Specifications |
Output |
Description |
Picture | Wiring diagram |
|
LCBP |
Light curtain controller |
AC 110~220V |
1NC+1NO |
Suitable for a set of lightweight curtains (7 cores - PNP). |
|
Wiring diagram for light curtain and LCBP |
| LCBN |
Light curtain controller |
AC 110~220V |
1NC+1NO |
Suitable for a set of lightweight curtains (7 cores - NPN). |
|
Wiring diagram for light curtain and LCBN |
|
SRC106 |
Safety relay |
DC 24V |
3NC+1NO |
Dual-channel, manual/automatic reset selectable(7 cores - PNP) |
|
Wiring diagram for light curtain and SRC106 |
|
SRC106.n |
Safety relay |
DC 24V |
3NC+1NO |
Dual-channel, manual/automatic reset selectable(7 cores - NPN) |
|
Wiring diagram for light curtain and SRC106.n |
Accessories Specifications
|
Name |
Picture |
Dimensions |
Application |
|
T-type screw |
|
|
|
|
CA02/Standard configuration |
For side groove installation method |
||
|
Side right-angle bracket |
|
|
|
| CA05/Standard | For CAT/CTT side fixation | ||
|
Convex nut |
|
|
|
|
CA03/Optional |
For side groove installation method |
||
|
Stainless steel pipe support |
|
|
|
|
CA01/Optional |
For tubular installation method |
||
|
Right-angle shock absorber |
|
![]() |
|
| CAT-01/Optional | For CAT/CTT two-end mounting method | ||
|
Side right-angle shock absorber |
![]() |
![]() |
|
| CAT-02/Optional | For CAT/CTT side fixation |
Light curtain wiring diagram
| PNP Wiring Diagram | NPN wiring diagram |
|
|
|
| ►For further questions, please contact customer service or check out the technical support section. |
Hot Tags: universal long-distance safety light curtain | cat 14-30-390 2bc cyndar, China, manufacturers, factory, buy, price, cheap, 2D Laser Scanner, agv safety edge, Edge sensor detects contact, Industrial Laser Scanner, Long Sensing Distance Light Curtain Guarding, Ultra Slim Safety Light Curtain Type4