CYNDAR Sensor Manufacturer
Offering retail and bulk orders, reliable quality, and superior service
Products Description
| safety light curtain | safety light curtain | |||
| Mode | CCE 50-30-1470 2BA | |||
| Features | Number of Optical Axes | Beam Spacing | Protective Height | Scan range |
| Illustration |
|
|
|
|
| Features | 50 beams | 30mm | 1470mm | 3m |
| Secure Outputs (OSSD) | 2 PNP NC | |||
| Interface Plug | M12 Connector | |||
| Package | 1 receiver and 1 transmitter, screw bracket accessories, 3-meter cable | |||
| synchronous | Line synchronization | |||
For more specifications, please refer to the user manual and contact customer service.
On the CCE 50-30-1470, 50 axes sit on 30 mm centres over a 1470 mm field. Its 38 mm resolution follows from the 30 mm spacing. Both columns measure 1508 mm in a 30 x 30 mm profile, a fit for forming station entries. The 30 x 30 mm section of the CCE 50-30-1470 takes the standard slotted brackets. Outputs are two PNP contacts, normally closed, on an M12 plug; the 2BA build reaches 0.3 to 3 m. For a 1470 mm gap the 50-30-1470 is the size to quote.
More product descriptions
|
Product Name |
Safety Light Curtain |
|||
|
Relevant parameters |
||||
|
Light curtain type |
Transmitter and receiver through-beam |
|||
|
Optical axis spacing |
10mm |
20mm |
30mm |
40mm |
|
Detection accuracy |
18mm |
28mm |
38mm |
48mm |
|
Number of light beams |
12,14...72 |
6,8...72 |
4,6...72 |
4,6...72 |
|
Protection height |
Optical axis spacing × (Number of beams - 1) |
|||
|
Detection distance |
0.3~3m(A);0.3~6m(B) |
|||
|
Electrical data |
||||
|
Power supply voltage |
DC12/24V |
|||
|
Consumption current |
≤200mA |
|||
|
Response time |
≤15ms |
|||
|
Output |
NPN/PNP type, sink current 500mA, voltage drop below 1.5V, polarity, short circuit, and overload protection. |
|||
|
Switching elements |
PNP transistor or NPN transistor |
|||
|
Controller |
Light curtain controller (AC110-220V relay output) |
|||
|
Safety relay (DC24V relay output, dual channel, manual/automatic reset selectable) |
||||
|
Output status |
When all optical axes are illuminated, the receiver is ON (green light indicates this). |
|||
|
Indicator light |
Transmitter: Power indicator (red); Receiver: Output indicator light - On (green) - Off (red) |
|||
|
Mechanical data |
||||
|
Wavelength |
940nm |
|||
|
Light source |
Modulated Infrared LED |
|||
|
Cross-sectional dimensions |
30mmx30mm |
|||
|
Shell material |
Aluminum alloy, end caps: ABS reinforced nylon |
|||
|
Electrical Interfaces |
||||
|
Number of Interfaces |
2 (Transmitter and Receiver) |
|||
|
Interface Types |
7-pin M12 connector |
|||
|
Connection method |
Circular aviation socket, with dedicated connecting cable |
|||
|
Environmental Data |
||||
|
Protection grade |
IP65 |
|||
|
Resistance to light interference |
10000lux(Incident angle ≥ 5°) |
|||
|
Resistance to ambient light |
Incandescent light: Light intensity on the receiving surface is 3000 lux; sunlight: Light intensity on the receiving surface is 10000 lux. |
|||
|
Ambient temperature |
Workshop: -10 - 40℃ (but not freezing), storage: -25 to 55℃ |
|||
|
Ambient humidity |
Workshop: 35 - 85% RH, storage: 35 - 95% RH |
|||
|
Packaging |
Standard packaging (foam and cardboard box) |
|||
|
Allowable cable length |
100m |
|||
Model Description
|
Example Model: CCE 50-30-1470 2BA Multi-beam Anti-interference Safety Light Curtain: 50 beams, 30mm optical axis spacing, 1470mm detection height, two sets of normally closed PNP outputs, 0.3-3m through-beam, 3m cable. |
|||||||
|
CCE |
50- |
30- |
1470 |
2 |
A |
A |
3m |
|
|
|
|
|
|
|
|
|
|
Product Series |
Number of beams |
Optical axis spacing |
Protection height |
Output quantity |
Output method |
Sensing distance |
Data cable length |
|
CCE |
04 06 08 ... 72 |
10:10mm 20:20mm 30:30mm 40:40mm |
Effective product height :Height = (Number of beams - 1) * Spacing |
2: Two sets of outputs |
A: NPN NC B: PNP NC C: NPN NO D: PNP NO |
A: 0.3-3M B: 0.3-6M |
Standard configuration: 3 meters (not specified) 4m: 4 meters 5m: 5 meters ... 30m: 30 meters |
Factory configuration

Controller optional
|
Model |
Name |
Specifications |
Output |
Description |
Picture | Wiring diagram |
|
LCBP |
Light curtain controller |
AC 110~220V |
1NC+1NO |
Suitable for single-sided 7-core PNP light curtain. |
|
Wiring diagram for light curtain and LCBP |
| LCBN |
Light curtain controller |
AC 110~220V |
1NC+1NO |
Suitable for single-sided 7-core NPN light curtain. |
|
Wiring diagram for light curtain and LCBN |
|
SRC106 |
Safety relay |
DC 24V |
3NC+1NO |
Dual-channel, manual/automatic reset selectable, suitable for 7-core PNP light curtains. |
|
Wiring diagram for light curtain and SRC106 |
|
SRC106.n |
Safety relay |
DC 24V |
3NC+1NO |
Dual-channel, manual/automatic reset selectable, suitable for 7-core NPN light curtains. |
|
Wiring diagram for light curtain and SRC106.n |
Accessories Specifications
|
Name |
Picture |
Dimensions |
Application |
|
T-type screw |
|
|
|
|
CA02/Standard configuration |
For side groove installation method |
||
|
Right-angle bracket |
|
|
|
|
CA04/Standard configuration |
For end mounting method |
||
|
Convex nut |
|
|
|
|
CA03/Optional |
For side groove installation method |
||
|
Stainless steel pipe support |
|
|
|
|
CA01/Optional |
For tubular installation method |
Light curtain wiring diagram
| PNP Wiring Diagram | NPN wiring diagram |
|
|
|
| ►For further questions, please contact customer service or check out the technical support section. |
Hot Tags: multi-beam anti-interference safety light curtain | cce 50-30-1470 2ba cyndar, China, manufacturers, factory, buy, price, cheap, automation direct light curtain, Highly sensitive safety edge for machine edge, ir sensor light curtain, overhead door safety edge, Safety Curtain Sensor For Hydraulic Press, wireless safety edge