CYNDAR Sensor Manufacturer
Offering retail and bulk orders, reliable quality, and superior service
Products Description
| safety light curtain | safety light curtain | |||
| Mode | CCT 32-20-620 2BB | |||
| Features | Number of Optical Axes | Beam Spacing | Protective Height | Scan range |
| Illustration |
|
|
|
|
| Features | 32 beams | 20mm | 620mm | 6m |
| Secure Outputs (OSSD) | 2 PNP NC | |||
| Interface Plug | M12 Connector | |||
| Package | 1 receiver and 1 transmitter, screw bracket accessories, 3-meter cable | |||
| synchronous | Line synchronization | |||
For more specifications, please refer to the user manual and contact customer service.
This 32-beam CCT curtain is sized for access protection on medium-size machine openings. Where the machine frame is narrow, the 30 x 30 mm profile keeps the curtain close to the opening. With 20 mm beam spacing the detection resolution is 28 mm, a figure worth matching against the actual gap in the machine guard. A 620 mm protected field usually covers 32 beams; confirm the mounting distance so the outer beams sit inside the opening.
More product descriptions
|
Product Name |
Safety Light Curtain |
|||||||
|
Relevant parameters |
||||||||
|
Light curtain form |
Firing method |
|||||||
|
Optical axis spacing |
10mm |
14mm |
20mm |
25mm |
30mm |
40mm |
80mm |
200mm |
|
Detection accuracy |
18mm |
22mm |
28mm |
33mm |
38mm |
48mm |
88mm |
208mm |
|
Number of light beams |
6,8...32 |
6,8...32 |
4,6...32 |
6,8...32 |
4,6...32 |
4,6...32 |
4,6...32 |
4,6...16 |
|
Protection height |
Optical axis spacing × (Number of beams - 1) |
|||||||
|
Detection distance |
0.3~3m(A);0.3~6m(B) |
|||||||
|
Electrical data |
||||||||
|
Power supply voltage |
DC12/24V |
|||||||
|
Consumption current |
≤200mA |
|||||||
|
Response time |
≤15ms |
|||||||
|
Output |
NPN/PNP type, with a current injection of 500mA, with a voltage drop of less than 1.5V, featuring polarity, short-circuit and overload protection. |
|||||||
|
Switching elements |
PNP crystal or/NPN transistor |
|||||||
|
Controller
|
Light curtain controller (AC110-220V relay output) | |||||||
|
Safety relay (DC24V relay output, dual channel, manual/automatic reset selectable) |
||||||||
|
Output state |
When all optical axes are illuminated, the receiver is ON (green light indicates this). |
|||||||
|
Indicator light |
Projector: Power indicator light (red); Receiver: Output indicator light is on (green) / blocked (red) |
|||||||
|
Mechanical data |
||||||||
|
wavelength |
940nm |
|||||||
|
Light source |
Modulated Infrared LED |
|||||||
|
Cross-sectional dimensions |
30mmx30mm |
|||||||
|
Shell material |
Aluminum alloy, end cover: ABS reinforced nylon. |
|||||||
|
Electrical Interfaces |
||||||||
|
Number of Interfaces |
2 (Transmitter and Receiver) |
|||||||
|
Interface Types |
7-pin, M12 connector |
|||||||
|
Environmental Data |
||||||||
|
Protection grade |
IP65 |
|||||||
|
Resistance to light interference |
10000lux(Incident angle ≥ 5°) |
|||||||
|
Resistance to ambient light |
Incandescent light: Light intensity on the receiving surface is 3000 lux; sunlight: Light intensity on the receiving surface is 10000 lux. |
|||||||
|
Ambient temperature |
Workshop: -10 - 40℃ (but not freezing), storage: -25 to 55℃ |
|||||||
|
Ambient humidity |
Workshop: 35 - 85% RH, storage: 35 - 95% RH |
|||||||
|
Packaging |
Standard industrial environment |
|||||||
|
Allowable cable length |
100m |
|||||||
Model Description
|
Example Model: CCT 08-40-280 2AA-5m Anti-interference Safety Light Curtain CCT: 8 beams, 40mm optical axis spacing, 280mm detection height, two sets of normally closed NPN outputs, 3m through-beam, 5m cable. |
|||||||
|
CCT |
08- |
40- |
280 |
2 |
A |
A |
-5m |
|
|
|
|
|
|
|
|
|
|
Product Series |
Number of beams |
Optical axis spacing |
Protection height |
Output quantity |
Output method |
Sensing distance |
Data cable length |
|
CCT |
04 06 08 ... 32 |
10:10mm 14:14mm 20:20mm 25:25mm 30:30mm 40:40mm 80:80mm 200:200mm |
Effective product height :Height = (Number of beams - 1) * Spacing |
2: Two sets of outputs |
A: NPN NC B: PNP NC C: NPN NO D: PNP NO |
A: 0.03-3M B: 0.03-6M |
Standard configuration: 3 meters (not specified) 4m: 4 meters 5m: 5 meters ... 30m: 30 meters |
Factory configuration

Controller optional
|
Model |
Name |
Specifications |
Output |
Description |
Picture | Wiring diagram |
|
LCBP1 |
Light curtain controller |
AC 110~220V |
1NC+1NO |
Suitable for a set of lightweight curtains (7 cores - PNP). |
|
Wiring diagram for light curtain and LCBP1 |
| LCBN |
Light curtain controller |
AC 110~220V |
1NC+1NO |
Suitable for a set of lightweight curtains (7 cores - NPN). |
|
Wiring diagram for light curtain and LCBN |
|
SRC106 |
Safety relay |
DC 24V |
3NC+1NO |
Dual-channel, manual/automatic reset selectable(7 cores - PNP). |
|
Wiring diagram for light curtain and SRC106 |
|
SRC106.n |
Safety relay |
DC 24V |
3NC+1NO |
Dual-channel, manual/automatic reset selectable(7 cores - NPN) |
|
Wiring diagram for light curtain and SRC106.n |
Accessories Specifications
|
Name |
Picture |
Dimensions |
Application |
|
T-type screw |
|
|
|
|
CA02/Standard configuration |
For side groove installation method |
||
|
Right-angle bracket |
|
|
|
|
CA04/Standard configuration |
For CCT end mounting method |
||
|
Convex nut |
|
|
|
|
CA03/Optional |
For side groove installation method |
||
|
Stainless steel pipe support |
|
|
|
|
CA01/Optional |
For tubular installation method |
Light curtain wiring diagram
| PNP Wiring Diagram | NPN wiring diagram |
|
|
|
| ►For further questions, please contact customer service or check out the technical support section. |
Hot Tags: anti-interference safety light curtain | cct 32-20-620 2bb cyndar, China, manufacturers, factory, buy, price, cheap, 3 beam light curtain, Automation Light Curtain Safety System, ir sensor light curtain, light curtain type 2, safety edge bumper strip, safety photoelectric sensor