sale1@cyndar.net    +86-18922155361
Cont

Have any Questions?

+86-18922155361

video

Safety relay SRC106 dual channel CYNDAR

Safety relay module meets EN/ISO 13849-1 Cat.4 safety requirements, suitable for high-security requirements of industrial site monitoring for various signal, including emergency stop-signal, the safety door switch signal, safety grating signal, the safety signal and hands button signal.

Product Introduction

The SRC106 relay module complies with the ISO 13849-1 safety standard and is suitable for monitoring various signals in industrial sites with high safety requirements, including emergency stop signals, safety door switch signals, safety grating signals, safety signals and hand button signals.

● The relay contacts are forced to be turned on, making monitoring more efficient and safer.
● The QSRC106 has a compact size and uses plug-in terminal connections for easy installation.
● The SRC106 relay module complies with the ISO 13849-1 safety standard and is suitable for monitoring various signals in industrial sites with high safety requirements, including emergency stop signals, safety door switch signals, safety grating signals, safety signals and hand button signals.

● The relay contacts are forced to be turned on, making monitoring more efficient and safer.
● The SRC106 has a compact size and uses plug-in terminal connections for easy installation.
● The SRC106 has four groups of control output signals, three groups of instantaneous normally open and one group of instantaneous normally closed, with strong control capabilities.

 

SRC106-Dual transistor signal control
● Can monitor two transistors, photoelectric switches, and safety gratings.
● With external circuits, it can also monitor two normally closed switch signals.
● All circuits have a self-checking function and automatically lock when the two signals are inconsistent.
● It has a wider adaptability to the residual voltage of the grating signal, and can still work stably when the residual voltage is greater than 10V.
● Can detect PNP signals and has strong adaptability.
● Automatic and manual reset are adjustable. In manual reset mode, the reset button is detected and a single reset is forced. The reset button must be disconnected for the next reset.

 

SRC106-Dual normally closed switch monitoring
● Monitor two normally closed switch signals, such as emergency stop buttons, safety door switches, etc.
● Monitor the short circuit between the two signals.
● Monitor the inconsistency of any single switch circuit, circuit breaker, and locking switch.
● Automatic and manual reset are adjustable. In manual reset mode, the reset button is detected and a single reset is forced. The reset button must be disconnected for the next reset.

 

SRC106-Manual button control
● Monitor manual button signals
● Button signal consistency detection, when the manual button trigger time is greater than 0.5 seconds, it is considered an invalid trigger.
● Independent dual circuits, full circuit self-check, lock when two signals are inconsistent. It has four groups of control output signals with three normally open and one normally closed, and has strong control capabilities.

 

-800-800-2

-800-800-3

-800-800-4

 

Technical Parameters

Power supply

Level 4

Voltage tolerance

±10%/-20%

Power Consumption

≤2.9W

Load Capacity

6A/250VAC/1500VA

6A/24VDC/150W

Protection

Housing IP30, terminal IP20, recommended to be installed in cabinet or housing IP54

Response Time

<20ms

Storage temperature

-40℃~105℃

Environmental Temperature

35%~95%RH

Housing material Flame retardant PA66
Mounting method Standard 35mm DIN rail/spring clip
Dimensions 114.5mm×100.5mm×22.5mm

 

FAQ

1. Q: How many sets of output are there in the conventional safety relays?

A: There are 3 normally open and 1 group normally closed, totally 4 sets of control output signals.

 

2. Q: Can the conventional safety relays set the self inspection function?

A: Yes, full loop self test. Lock when two signals are inconsistent.

 

3. Q: Can the conventional safety relays be reset manually?

A: Automatic and manual reset can be adjusted.Under manual reset mode, reset button can be detected. Forced on single reset, the reset button must be disconnected after the next reset operation.

 

4. Q: Which safety levels can the conventional safety relays meet?

A: Level 4

 

5. Q: What is the voltage of the conventional safety relays?

A: The voltage of the safety relay is DC24V + 10%.

 

Hot Tags: Safety relay SRC106 dual channel CYNDAR, China, manufacturers, factory, buy, price, cheap, cascading safety relays, Sensor safety edge protection, electrical safety relays, safety relay in transformer, safety control relays, safety relays for machinery