sale1@cyndar.net    +86-18922155361
Cont

Have any Questions?

+86-18922155361

Dual-channel Multifunctional Safety Relay With Reset Switch

Dual-channel Multifunctional Safety Relay With Reset Switch

Safety relays use redundant design (such as dual-channel signal monitoring), forced guide contact structure and self-test function to ensure that the circuit is forced to disconnect in the event of a fault, meeting safety standards such as ISO 13849; ordinary relays only realize circuit on and off, without a fail-safe mechanism, and cannot be used in personal protection scenarios.

Product Introduction

SRC106 Safety Relay
 

For more information, please refer to the manual

 

Check and monitor the safety system, start the machine or execute a command to stop the machine.

 

For small machines that require special logic devices to implement safety functions.

 

Dual-channel single-function safety relays are a more economical solution

 

SRC106 meets a variety of functional safety standards
 

Compliant with ISO13849-1 PLe standard and IEC 62061 SiL3 standard

 

Proven dual-channel safety monitoring circuit design

 

Multi-function configuration dip switch, suitable for a variety of safety sensors

 

Input and output LED indication

 

Auto/manual reset lever, quick configuration system

 

Width 22.5mm, reducing installation space

 

Optional screw terminals or spring terminals, wider range of applications

 

PLC signal output

 

Suitable for monitoring
 

Technical Parameters

Safety sensor Emergency stop button Safety switch Safety door lock

Forced safety output

3NO/1NC

22222

Applicable industries

 


Injection molding machines, CNC machine tools
Presses/hydraulic presses, glass machinery, filling machinery, packaging machinery
Sorting machinery, woodworking machinery, papermaking machinery
Intelligent forklifts, AGV, robots, elevators
Wind power, SIS systems, etc.

-1

 

 

2

3

4

5

6

7

 

 

 

-800-800-1

-800-800-2

 
FAQs about safety relays

Q: 1. What is the difference between safety relays and ordinary relays?

A: Safety relays use redundant design (such as dual-channel signal monitoring), forced guide contact structure and self-test function to ensure that the circuit is forced to disconnect in the event of a fault, meeting safety standards such as ISO 13849; ordinary relays only realize circuit on and off, without a fail-safe mechanism, and cannot be used in personal protection scenarios.

Q: 2. Which international standards must safety relays comply with?

A: Core standards include:
ISO 13849-1 (Performance level requirements for mechanical safety control systems)
IEC 62061 (Functional safety assessment framework)
EN 60947-5-1 (Low-voltage switchgear specification)
IEC 61508 (Functional safety basic standard).

Q: 3. In which scenarios must safety relays be used?

A: High-risk equipment involving personal safety must be configured compulsorily, such as stamping machinery, collaborative robot workspaces, automated logistics sorting lines, injection molding machine protective doors, elevator emergency braking systems, etc.

Q: 4. Why can dual-channel design improve safety?

A: The dual channels detect contact adhesion or short circuit faults by cross-checking two independent signals. For example, when one signal is abnormal, the safety relay can trigger the redundant channel to cut off the power supply within 15ms to avoid the risk of single point failure.

 

 

 
 