This safety relay module complies with the safety requirements of EN/ISO 13849-1 and is suitable for industrial field monitoring with high safety requirements for various signals (including emergency stop signals, safety door switch signals, safety grating signals, safety signals and two-hand button signals, series safety relays, AC and DC safety relays).
Safety relay wiring technical parameters
Safety rated control relay power supply voltage: DC24V±10%
Safety control relay power consumption: ≤3W
Load capacity: AC-1-6A/250VAC/1500VA
DC-1-6A/24VDC/150W
Waterproof grade: IP54
Response time: <30ms
Safety control: -10~55℃
Ambient temperature: 35%~95%RH
Impact withstand voltage: 2.5kV
Service life: 80,000 times
Dimensions of mechanical safety relay: 114.5mm×100.5mm×22.5mm
So why do so many industries use safety relays?
The main reasons are as follows. Safety relays are different from ordinary relays. Safety relays can ensure safety even when the contacts are melted, and the operating life of the contacts is more than 10 million times. Secondly, the safety relay is composed of multiple relay modules to prevent dangerous items caused by machine operators' mistakes or machine failures.
For example: a safety relay can be applied when the electromagnetic lock is switched on and off to ensure the safety of the work area.
The emergency stop switch is used when stopping the machine in an emergency
Use the safety limit switch to detect the position of the door and use it when opening or closing
Use safety gratings to prevent workers from entering dangerous working areas
When using two hands to press the switch, use when confirming that the machine operator has left the dangerous work area with both hands









FAQ
1. How many output groups does a conventional safety relay have?
The control output signal has 3 groups of normally open and 1 group of normally closed.
2. How to pay?
We provide 2 payment methods:
1) Wire transfer
5) PAYPAL
3. Can conventional safety relays be reset manually?
Automatic and manual reset are adjustable. In manual reset mode, the reset button can be detected. After a forced single reset, the reset button must be disconnected for the next reset operation.
4. What safety levels can conventional safety relays achieve?
Level 4
5. What is the voltage of conventional safety relays?
The voltage of the safety relay is DC24V±10%.